Key takeaways: how well do microbubbles work for equipment parts and rinsing?
In an MFC (mass flow controller) maker's parts cleaning evaluation, 9 ionic residues totaling approx. 420 ng/cm² were measured before cleaning and approx. 9 ng/cm² after — a reduction of about 98%; chloride fell from approx. 147 to 1 and sodium from approx. 118 to 1.5 ng/cm². A device maker evaluating the rinse step of its cleaning tool replaced ordinary ultrapure water with oxygen microbubble water and cut rinse time by 20%; at the same flow rate, rinse water use also falls by 20%, so the maker began evaluating a microbubble retrofit to its existing cleaning tools. These are test data from our customers; actual results must be confirmed with a controlled trial on your own parts and equipment.
MFC parts cleaning: all 9 ions decreased
MFCs sit on the gas lines of semiconductor equipment and precisely control the flow of each process gas. Ions such as chloride, sodium and potassium left on the parts can corrode the gas lines or be carried by the gas into the chamber and contaminate wafers, so MFC parts must be cleaned to very low ionic residue before assembly. For a comparison of cleaning methods for other equipment parts, see “How semiconductor equipment parts are cleaned”.
| Ion | Before cleaning | After cleaning |
|---|---|---|
| Chloride Cl⁻ | approx. 147 | approx. 1 |
| Sodium Na⁺ | approx. 118 | approx. 1.5 |
| Potassium K⁺ | approx. 63 | below 0.5 |
| Calcium Ca²⁺ | approx. 55 | approx. 3.5 |
| Sulfate SO₄²⁻ | approx. 18 | approx. 1 |
| Nitrate NO₃⁻ | approx. 8 | below 1 |
| Magnesium Mg²⁺ | approx. 6 | near 0 |
| Ammonium NH₄⁺ | approx. 4.5 | near 0 |
| Phosphate PO₄³⁻ | approx. 2.5 | approx. 1 |
| Total | approx. 420 | approx. 9 (about 98% lower) |
Values were read from the original bar chart and are approximate; lithium, fluoride, nitrite and bromide were near 0 both before and after cleaning and are not listed. The cleaning conditions (gas type, time, temperature) were not disclosed.
Cleaning tool rinse: oxygen microbubble water cuts rinse time by 20%
Every chemical step in wet cleaning is followed by an ultrapure-water rinse, and rinsing is one of the most water-intensive steps in a cleaning tool. A device maker replaced its rinse ultrapure water with oxygen microbubble water and compared the time needed to reach the same rinse result:
With the rinse time of ordinary ultrapure water set to 1, oxygen microbubble water took 0.8. How the rinse endpoint was determined was not disclosed.
A 20% shorter rinse means 20% less rinse water at the same flow rate, and higher cleaning tool throughput. Because of this water saving, the device maker is evaluating adding microbubbles to its existing cleaning tools rather than buying new ones. For other ways fabs save water, see “Water-free cleaning”.
Why do microbubbles make rinsing more efficient?
The current explanation: microbubbles carry a negative charge in pure water, so they can adsorb contaminants and carry them off the surface; experimental results also suggest that water containing microbubbles has lower surface tension than ordinary pure water, making it easier to get into narrow gaps. Both points are still hypotheses, and actual results need to be verified on your own equipment. For an illustrated explanation of how microbubbles work, see “What is microbubble cleaning in semiconductors”.
3 lessons from this data
- For parts cleaning, look at ions, not just particles: for gas-line parts like MFCs, chloride, sodium and potassium residues matter more than visible dirt.
- Rinsing is the easiest place to start: no chemical changes, no process changes — just switch the rinse water to microbubble water, for the lowest risk.
- It can be retrofitted to existing tools: the device maker evaluated adding a microbubble supply unit to the rinse line of its current cleaning tool, with no need to replace the whole machine.
Data sources and limitations
The data on this page is test data from our customers' evaluation period (c. 2019), when the evaluations were still in progress; customer names are withheld under confidentiality.
Figures were read from the original charts and are approximate. DEYly has not independently retested them, and actual results will vary with contaminants, materials, equipment and process conditions; before adopting, please confirm with a controlled trial on your own samples.
FAQ
Can microbubbles clean semiconductor equipment parts?
Yes. In an MFC (mass flow controller) maker's evaluation, the total of 9 ionic residues on the parts fell from approx. 420 to approx. 9 ng/cm², about 98% lower; chloride fell from approx. 147 to 1 and sodium from approx. 118 to 1.5 ng/cm².
How much time and water can rinsing with microbubble water save?
In a device maker's evaluation, oxygen microbubble water took 0.8 times as long to rinse as ordinary ultrapure water, 20% shorter; at the same flow rate, rinse water use also falls by 20%.
Can microbubbles be retrofitted to existing cleaning tools?
Yes. A microbubble supply unit can be connected to the rinse line of an existing cleaning tool, which is exactly the retrofit the device maker evaluated. Before installing, confirm the line's flow rate, pressure and wetted materials.
Whose data is this?
Customer names are withheld under confidentiality. This is our customers' evaluation data from c. 2019; at the time, the MFC maker's evaluation was ongoing and the device maker was evaluating a retrofit.