Cleaning Trial & Evaluation

Semiconductor wafer & parts cleaning trial:
your wafers, your contaminants, tested before you decide

The cleaning process trial evaluation is DEYly’s pre-adoption assessment service for semiconductor cleaning: we trial-clean the customer’s actual wafers, equipment parts or chemical filters with one or more of microbubble, CO₂ snow and supercritical CO₂ cleaning at the OEM or a partner laboratory. Before any cleaning starts, both sides sign off a trial plan (sample grouping, trial conditions, measurement items, pass criteria); afterwards you receive an evaluation report including production feasibility, in Chinese with optional English or Japanese. From plan sign-off to report delivery usually takes 2–4 weeks, and the requirements meeting is free of charge. It is for process and equipment engineers who want to switch cleaning methods, are stuck with their current cleaning, or have run a PoC whose results everyone reads differently. Other people’s sample data proves little; test with your own chips and your own contaminants before you decide.

MicrobubblesCO₂ snowSupercritical CO₂Wafers · parts · filter cartridgesDirect liaison with OEMs in EN / JP / ZH

Key takeaways: what is a trial evaluation? Process, deliverables, timeline and cost

A cleaning process trial evaluation is a controlled trial cleaning and feasibility assessment that DEYly runs on the customer’s own wafers, equipment parts or chemical filters before the customer decides to adopt microbubble, CO₂ snow or supercritical CO₂ cleaning. Six steps: problem definition and method recommendation → trial plan (sample grouping, conditions, control group, measurement items, pass criteria, signed off by both sides before work starts) → execution at the OEM or a partner laboratory with conditions logged per batch → before/after measurement and interpretation → production feasibility (time per piece, hourly throughput, consumable and gas usage, footprint and safety) → evaluation report and next steps. The deliverable is a report in Chinese (English or Japanese optional) that records only measured figures and the basis for each inference; poor results are reported as they are, and no technology is endorsed. Timeline: usually 2–4 weeks from plan sign-off to report delivery. Cost: the requirements meeting is free; the trial is quoted by sample count, method and measurement items, and can be credited against later equipment purchases under contract. Confidentiality: an NDA is signed before the trial, samples are destroyed or returned afterwards, and measurement data belongs to the customer. Test results: in existing evaluations of microbubble cleaning, photoresist stripping ran about 50% faster than ozone water, metal contamination on wafers fell by 2–3 orders of magnitude, and ionic residue on equipment parts dropped about 98% (see test results); conditions differ from fab to fab, so verify with your own samples. For how to choose a cleaning vendor and when to trial before buying equipment, see How to choose a semiconductor cleaning vendor.

Does this sound familiar?

You want to change cleaning method, but…

  • The vendor's data comes from someone else's samples and does not match your process
  • All three technologies have advocates, and you do not know which to try first
  • You worry the trial will work but production throughput will not keep up

Your current cleaning is stuck, but…

  • Particles will not come off, and adding force starts damaging the structures
  • Residue and watermarks remain after drying, and extra rinse steps have not helped
  • Particles are too small for inspection to see, and you cannot prove the surface is clean

You have run a PoC, but…

  • Pass criteria were never agreed before the trial, so everyone reads the report differently
  • Trial conditions were too far from production conditions for the results to mean anything
  • Sample confidentiality and data ownership were never settled, so you dare not send real chips

Trial evaluation: what we deliver

01

Problem definition and method recommendation

We first pin down whether you are solving particles, damage or residue, match it to the contaminant and material, and recommend which method to try first and why.

02

Trial plan

Sample count and grouping, trial conditions, control group, measurement items and pass criteria, signed off together before work starts so there is no arguing afterward.

03

Trial execution

Run to plan at the OEM or a partner lab, with conditions logged batch by batch; you can attend and witness if needed.

04

Before-and-after measurement and interpretation

Measured and interpreted against the items in the plan, with cleaning effect and material compatibility assessed separately and a clear note of what was measured directly and what was inferred.

05

Production feasibility assessment

Per-piece time, hourly throughput, consumable and gas usage, equipment footprint and safety requirements, converted to your process step.

06

Evaluation report and next steps

A report in Chinese (English or Japanese available): conclusions, data, limitations, the recommended step and conditions for adoption, or the reasons if adoption is not recommended.

The report contains only measured figures and the basis for each inference. If the trial goes badly, the report says so. We do not pad it with estimates, and we do not endorse any one technology.

What can be trialed

Three methods and what they suit
MethodProblems it suitsTypical objects
microbubble cleaningWet-process steps where "more force means damage"; organic residue, particlesWafers, photoresist residue, FOUP / FOSB and other carriers, equipment parts
CO₂ snow cleaningSurfaces that cannot take water, cannot tolerate residue, or need fine-particle removalWafer backside and edge, MEMS, pre-bonding surfaces, parts such as showerheads and shields
Supercritical CO₂Drying high-aspect-ratio structures, deep cleaning of porous materialsDrying patterned wafers, chemical filter regeneration, precision parts

The same sample set can also be split so two methods are compared side by side. Precision parts, optical components and medical devices outside semiconductors are also accepted for evaluation.

Test results: what microbubble cleaning measured

Each result below comes from a company evaluating its own samples under its own conditions, and each has a full case page with the conditions, figures and limitations.

Photoresist strip about 50% faster

Major chipmaker evaluation: at the same 80 ppm ozone, ozone microbubbles stripped resist at about 2,150 → 3,370 Å/min; in lab tests, phosphorus-implanted hardened resist was removed in 3 minutes without ashing. View case →

Metal residue down 2–3 orders of magnitude

Power device maker evaluation: ozone microbubbles plus dilute HF (DHF) brought Cu, Fe, Ni and Al on wafers below 1/100 of initial levels. View case →

Parts ionic residue down 98%

MFC maker evaluation: total residue of 9 ion species on parts fell from about 420 to 9 ng/cm²; a device maker rinsing with oxygen microbubble water cut rinse time by 20%. View case →

Figures change with the contaminant, material and conditions, and another fab's results cannot be applied directly to your process. That is exactly why you should trial with your own samples first.

How we work

  1. Requirements review (one meeting)

    We learn the process step, contaminant, material, current cleaning method and where it is stuck, and confirm which problem to solve.

  2. Confidentiality and sample agreement

    Sign an NDA and agree sample count, shipping, post-trial handling and data ownership.

  3. Trial plan sign-off

    Grouping, conditions, control group, measurement items and pass criteria on one page, confirmed by both sides before anything starts.

  4. Trial and measurement

    Run to plan, typically 2–4 weeks depending on sample count and measurement items.

  5. Report and next-steps meeting

    We deliver the report and discuss together: which step to adopt at, what to test next, or whether the conclusion is that it does not fit.

Why DEYly

All three methods available, not tied to one

The technologies we represent and partner with cover microbubbles, CO₂ snow and supercritical CO₂. Our recommendation follows your problem, not what we would like to sell.

We understand the process and your step

The team brings 13 years in semiconductors and 20 years in automation equipment, and knows how trial conditions differ from production.

Pass criteria agreed up front

What to measure, how many samples, what counts as a pass: written into the plan and signed off before the trial, so the report never turns into a dispute.

Direct liaison with OEMs in EN / JP / ZH

Technical questions go straight to engineers at Japanese and overseas OEMs, with no translation relay.

Want to understand the technology first?

How each of the three methods works and what it solves is covered in our Insights articles:

Why legacy cleaning falls short at 2 nm →Three ways to clean with CO₂ compared →Dry vs. wet cleaning: 8 methods compared →
Not sure where to start? See how all our solutions fit together.Solutions overview →

FAQ

Is the trial evaluation paid?

The requirements review meeting is free. The trial itself is quoted by sample count, method and measurement items; if you go on to adopt the equipment, the trial fee can be credited under the contract.

How long does a trial take?

Typically 2–4 weeks from plan sign-off to report delivery. More samples or more measurement items (for example, outsourced ICP-MS or SEM) take longer; the plan states the timeline.

What do I need to prepare?

At a minimum: the problem to solve, a description of the contaminant and material, the current cleaning method, and how many samples you can provide. Existing measurement data or failure photos help.

How are samples and data kept confidential?

An NDA is signed before the trial, covering sample shipping and post-trial destruction or return. Measurement data belongs to the customer; neither DEYly nor the OEM cites it externally.

What if the trial results are poor?

The report says so, explains the likely causes, and states whether it is worth retrying with different conditions or a different method. "Not suitable" is a valuable conclusion too: it saves the cost of finding out after adoption.

How effective is microbubble cleaning in practice?

In existing evaluations: at a major chipmaker, ozone microbubbles stripped photoresist about 50% faster than ozone water at the same 80 ppm ozone; at a power device maker, adding dilute HF cut Cu, Fe, Ni and Al on wafers by 2–3 orders of magnitude; at an MFC maker, ionic residue on parts fell about 98%. These are each fab's results under its own conditions. With your contaminants and materials the numbers will differ, so trial with your own samples first.

If the trial works, does that mean production will work?

Not necessarily, which is why the report has a separate production-feasibility section: throughput, consumables, safety and footprint. We recommend a small-scale rollout at a single step first, verified again under production conditions.

Plan first

Agree the criteria before the trial, and the report will be worth something

The requirements review meeting is free. Bring the problem, the contaminant and material, and your current cleaning method, and we define the trial plan together.