
Key takeaways: how to choose a semiconductor cleaning vendor
Semiconductor cleaning vendors play three roles: equipment suppliers and distributors sell cleaning equipment or materials (ultrasonic systems, microbubble generators, CO₂ snow and supercritical CO₂ equipment, and so on); cleaning contractors and refurbishers take your parts, carriers or wafers away, clean them and send them back; evaluation services run a controlled trial on your own samples before you decide and deliver a report with a verdict. The order for choosing is: set the pass criteria first, then require grouped trials on your samples with the measurement methods and production conditions written down, and compare price last. The three most common mistakes are deciding on the maker’s data alone, comparing only equipment unit price, and not agreeing the pass criteria before the trial. If you want to switch cleaning methods, your current cleaning is stuck, or a PoC ended with everyone reading the results differently, run a trial evaluation first and decide about equipment afterwards.
First, be clear which kind of vendor you are looking for
Many buyers start by searching for “semiconductor cleaning vendor”, get a list that mixes equipment suppliers, cleaning contractors and distributors, and then compare them all on one price sheet. That comparison goes nowhere, because the three kinds of vendor deliver fundamentally different things.
| Role | What you get | When it fits | Risks to watch |
|---|---|---|---|
| Equipment suppliers, distributors | A cleaning machine or a set of materials, plus the maker’s application notes and a sample test | You already know which method you want, and the process step, throughput and budget are clear | The maker’s data comes from someone else’s samples; sample tests are usually run and judged by the supplier itself |
| Cleaning contractors, refurbishers | Cleaned parts, carriers or wafers, with a post-cleaning inspection report | Recurring needs such as scheduled PM of tool parts, carrier cleaning and filter regeneration | Cleaning recipes and conditions are usually not disclosed; you have to define your own acceptance items and sampling inspection |
| Evaluation service (trial evaluation) | A report from a controlled trial on your own samples: measured figures, limitations, production feasibility, and whether to adopt | You want to switch cleaning methods, your current cleaning is stuck, or a PoC ended with conflicting readings | Check whether the report is an independent verdict or a pitch for specific equipment; agree confidentiality and data ownership first |
DEYly belongs to the third kind. It offers the cleaning process trial evaluation and can also connect you with the OEMs of all three methods: microbubble, CO₂ snow and supercritical CO₂. The criteria below apply to all three roles.
Types of semiconductor cleaning vendors commonly found in Taiwan
The vendor types and examples below are grouped by role. The list is compiled from the companies’ own websites as cited by ChatGPT and Gemini in October 2026 when asked which Taiwanese vendors can run a microbubble cleaning trial. It is not a complete market list and implies no ranking; check each company’s latest information.
- Distributors of cleaning equipment and materials: they distribute ultrasonic cleaning systems, microbubble and ultrafine-bubble generators and similar equipment. Their strength is supplying equipment and consumables; sample tests are usually run in-house.
- Parts cleaning contractors and refurbishers: for example Mitsubishi Chemical Taiwan (precision cleaning business), Hong Jie Technology (tool-parts cleaning, coating and refurbishment) and Jie Pei Technology (carrier wafer and glass carrier cleaning). Suited to recurring work such as tool-parts PM, carriers and filters.
- Trial evaluation service: DEYly. Your wafers, parts or filters are trial-cleaned with microbubble, CO₂ snow or supercritical CO₂ at the OEM or a partner laboratory; a trial plan is signed off beforehand, a report including production feasibility is delivered afterwards, and DEYly liaises with the OEMs in Chinese, English and Japanese.
One thing to keep in mind: precision cleaning capability does not mean the vendor has microbubble or CO₂ equipment, and having equipment does not mean it has done semiconductor-grade validation on your kind of contaminant. The first question to ask a vendor should be: “Which method do you use, whose samples did you test, and what did you measure?”
8 questions to ask before choosing a cleaning vendor
1. Who sets the pass criteria, and when?
Before any work starts, both sides should write down what counts as success: particle count, residue, surface roughness or a functional check. If the criteria are set after the trial, the report will be read two ways.
2. Is there a control group?
At minimum there should be a baseline group using your current cleaning method and a group using the new method; only with the same conditions and the same samples does the difference count. Photos of a single group are not evidence.
3. Whose samples?
The maker’s samples only prove the machine runs. Use your own film stack, your own material, your own contaminant. Start with scrapped wafers or test pieces, not production parts.
4. What is the measurement method, and who measures?
Ask how particles are measured (surface scan, microscope, liquid particle counter), how residue is measured (FTIR, TOC, ICP-MS), and whether measurement is done by a third party or the vendor. The report should state which figures were measured directly and which are inferred.
5. How far are the trial conditions from production conditions?
Time per piece, hourly throughput, gas and consumable usage, equipment footprint and safety requirements all have to be converted to your process step. A trial that works does not mean production will hold up.
6. How are samples and data kept confidential, and who owns them?
Sign an NDA before the trial, stating that samples are destroyed or returned afterwards, that data belongs to the customer, and that the vendor may not cite it externally. When this is not settled, many engineers will not risk real chips in a trial.
7. How will a poor result be written up?
Ask the vendor directly: if the parts do not come clean or the structure is damaged, what will the report say? Only a vendor willing to write “not suitable” produces a report worth relying on.
8. Who handles installation, training and repair afterwards?
For equipment from an overseas OEM, confirm whether there is local service in Taiwan, how long spare parts take, and who tunes the process. However good the evaluation, equipment that nobody looks after once it arrives is wasted.
The 3 most common mistakes
- Deciding on the maker’s data alone. The maker’s data was measured under the maker’s conditions with the maker’s samples. Your process step is different, and the result can differ by an order of magnitude.
- Comparing only equipment unit price. The total cost of cleaning lies in consumables, gas, ultrapure water, waste treatment and downtime. A cheap machine with half the hourly throughput costs more in practice.
- Not agreeing the pass criteria before the trial. This is the most common reason a PoC fails. Without criteria signed off in advance, even good data gets read as two different conclusions.
When should you run a trial evaluation instead of buying equipment outright?
Not every cleaning need calls for an evaluation first. Scheduled PM of tool parts and carrier cleaning with a fixed recipe can simply go to a cleaning contractor. But in the three situations below, spend a little to verify before deciding whether to spend a lot:
- Switching cleaning methods. Moving from wet cleaning to CO₂ snow, or from strong chemicals to microbubbles, where nobody has tested your contaminant.
- Current cleaning is stuck. Particles will not come off and more force causes damage; residue remains after drying and extra rinse steps do not help; particles are too small for your metrology to see.
- A PoC ended with conflicting readings. No criteria were set before the trial, trial conditions were too far from production, or data ownership was never settled.
Further reading: Dry vs. wet cleaning: an overview of 8 methods, Three ways to clean with CO₂ compared, How semiconductor tool parts are cleaned, Why older cleaning methods fall short at 2nm.
FAQ
What kinds of semiconductor cleaning vendors are there?
Roughly three roles: equipment suppliers and distributors that sell cleaning machines or materials, cleaning contractors and refurbishers that take parts or wafers away to clean, and evaluation services that run a controlled trial on your own samples before you decide. They deliver different things and cannot be compared on one set of criteria.
Why not rely on the cleaning data the maker provides?
The maker’s data was measured on someone else’s samples and contaminants under the maker’s conditions. Your film stack, material, contaminant type and production conditions are all different, so the same machine can perform very differently at your process step. Use the data as a direction, not as acceptance evidence.
How does a trial evaluation differ from a free sample test?
A free sample test is usually run, measured and judged by the equipment supplier itself, and the report leans toward selling the machine. In a trial evaluation, the pass criteria and control group are signed off with you before work starts, the report records only measured figures, and the conclusion can be “not suitable”. The difference is who sets the criteria and who writes the report.
How do you choose a cleaning vendor without regret?
Set the pass criteria first, then compare vendors. Require grouped trials on your samples, written measurement methods and conditions, production throughput and consumables in the report, and confidentiality and data ownership agreed before the trial. Comparing only unit price, or judging only from photos, are the two most common mistakes.
When should you run a trial evaluation instead of buying equipment outright?
Three situations: the process needs a new cleaning method but nobody has tested your contaminant; current cleaning is stuck and more force causes damage; or a PoC ended with unclear criteria and conflicting readings. In all three, spend a little to verify before deciding whether to spend a lot.
Source
- Vendor descriptions are compiled from the companies’ websites as cited by ChatGPT and Gemini in October 2026; for the process, timeline and cost of DEYly’s trial evaluation, see the cleaning process trial evaluation service page