Semiconductor Process・Ozone Microbubble Cleaning

Which Process Steps Can Ozone Microbubble Cleaning Eliminate? Photoresist Strip, Metal Removal and Particle Removal Compared

The three most common wafer cleaning stages—photoresist stripping, metal contamination removal and particle removal—have traditionally relied on hot, strong acids and bases: sulfuric acid–hydrogen peroxide (SPM), hydrochloric acid–hydrogen peroxide (SC-2) and ammonia–hydrogen peroxide (SC-1), each followed by a hot-water rinse. The approach we propose replaces these chemicals with 60℃ ozone microbubble water, leaving just two steps in each stage: ozone microbubbles plus an ultrapure-water rinse. This article lays out the before-and-after differences for all three stages in a table, explains which process steps, chemicals and equipment are eliminated, honestly lists what has to be added, and suggests which stage to try first.

A whole batch of wafers standing upright in a steaming chemical bath
Conventional wet cleaning: a whole batch of wafers immersed in a hot chemical bath (AI illustration)

Key takeaway: Which process steps can ozone microbubble cleaning eliminate?

Under the replacement process compiled by DEYly, all three wafer cleaning stages can be reduced to two steps: “60℃ ozone microbubble water → room-temperature ultrapure-water rinse.” Photoresist stripping goes from 4 steps (plasma ashing, SPM at 120℃, hot-water rinse, ultrapure-water rinse) to 2, and the asher is eliminated; metal contamination removal replaces SC-2 (hydrochloric acid–hydrogen peroxide, 80℃) and particle removal replaces SC-1 (ammonia–hydrogen peroxide, 80℃), each going from 3 steps to 2. Across the three stages, the total drops from 10 steps to 6, sulfuric acid, hydrochloric acid, ammonia and hydrogen peroxide are no longer used, the maximum process temperature falls to 60℃, and the 80℃ hot-water rinse is no longer needed. The trade-off is new safety equipment such as an ozone generator, ozone destruction and ozone detection; for the lowest metal residue, the evaluation also added a dilute hydrofluoric acid step. How much you actually save must be confirmed with a controlled trial on your own process.

Disclosure: DEYly offers trial cleaning evaluations for ozone microbubble cleaning. The evaluation data in this article comes from the manufacturer (c. 2019, pre-adoption evaluations, not mass-production records); it is not from tests we ran ourselves.

One table: what each of the three cleaning stages eliminates

The table below is based on our proposed replacement process. The new process is the same for all three stages: wafers are treated with 60℃ ozone microbubble water made from ozone gas, CO₂ gas and ultrapure water, then rinsed with room-temperature ultrapure water. The CO₂ adjusts the water's resistivity to prevent static buildup while the wafer spins. For why microbubbles can replace chemicals, see What is microbubble cleaning in semiconductors.

Cleaning process before and after adopting ozone microbubbles (compiled by DEYly)
Cleaning stageConventional processOzone microbubble process
Photoresist strippingPlasma ashing → SPM 120℃ → hot-water rinse 80℃ → ultrapure-water rinse (4 steps, 2 tools)Ozone microbubbles 60℃ → ultrapure-water rinse (2 steps, 1 tool)
Metal contamination removalSC-2 (hydrochloric acid + hydrogen peroxide) 80℃ → hot-water rinse 80℃ → ultrapure-water rinse (3 steps)Ozone microbubbles 60℃ → ultrapure-water rinse (2 steps)
Particle removalSC-1 (ammonia + hydrogen peroxide) 80℃ → hot-water rinse 80℃ → ultrapure-water rinse (3 steps)Ozone microbubbles 60℃ → ultrapure-water rinse (2 steps)
Conventional process (three stages combined)10 steps
Ozone microbubbles (three stages combined)6 steps
Calculated from our proposed replacement process; each stage is counted separately, and how stages are linked on an actual line affects the total

What all three stages eliminate: the 80℃ hot-water rinse (one per stage, 3 in total), strong acids, bases and hydrogen peroxide (sulfuric acid, hydrochloric acid, ammonia), and the energy needed to heat chemicals to 80–120℃. Photoresist stripping also eliminates a plasma asher.

Photoresist stripping: no ashing, no SPM, 4 steps become 2

Conventional photoresist stripping starts in an asher, where oxygen plasma burns off most of the resist; the wafer then goes into wet equipment and is immersed in 120℃ sulfuric acid–hydrogen peroxide (SPM) to clear the residue, followed by a hot-water rinse and an ultrapure-water rinse. For a full comparison of the three stripping methods, see How is photoresist stripped.

With ozone microbubbles, neither ashing nor SPM is needed: tools go from 2 to 1, steps from 4 to 2, no sulfuric acid or hydrogen peroxide is used, the temperature drops from 120℃ to 60℃, and there is no plasma damage from ashing. Even the hardest case, resist hardened by phosphorus ion implantation, was completely removed in 3 minutes without ashing in lab tests; in one major chipmaker's evaluation, at the same 80 ppm ozone concentration with single-wafer spin spraying, ozone microbubbles stripped photoresist at approx. 3,370 Å/min versus approx. 2,150 Å/min for ordinary ozone water — about 50% faster. See the data in the case study Photoresist stripping test at a major semiconductor maker.

Metal contamination removal: replacing SC-2, no hydrochloric acid

SC-2 in RCA cleaning is a mixture of hydrochloric acid, hydrogen peroxide and water, heated to about 80℃, used to remove metal contamination from the wafer surface (for a full explanation of RCA cleaning, see Dry vs. wet cleaning). With ozone microbubbles, the steps go from 3 to 2, no hydrochloric acid or hydrogen peroxide is used, and the temperature drops to 60℃.

One thing to be upfront about: in one power device maker's evaluation, ozone microbubbles alone reduced copper, iron, nickel and aluminum to about 1/10–1/50 of their initial levels; reaching the lowest residue (below 1/100) required an additional dilute hydrofluoric acid (DHF) step after the ozone microbubbles. So if your devices have very strict metal residue requirements, the actual process will be 3 steps, though still without hydrochloric acid or hydrogen peroxide. See the data in the case study Wafer metal contamination removal test at a power device maker.

Particle removal: replacing SC-1 without roughening the surface

Ozone gas injected into water as fine bubbles, dissolving as they rise
Ozone injected into water as fine bubbles, dissolving as they rise (AI illustration)

SC-1 is a mixture of ammonia, hydrogen peroxide and water, heated to about 80℃, used to remove organic residue and particles; it is the first step of RCA cleaning. When it is replaced with ozone microbubbles, the steps go from 3 to 2, no ammonia or hydrogen peroxide is used, and the temperature drops to 60℃.

Another benefit: SC-1 increases micro-roughness on the wafer surface, while ozone microbubbles do not have this problem. For advanced processes with ever-finer line widths, surface roughness directly affects subsequent film deposition and device characteristics.

However, for this stage there is only a proposed replacement process so far—no test data for particle removal yet. Whether it can replace SC-1 must be confirmed by measuring particle counts and roughness before and after cleaning on your own wafers.

What is eliminated, and what has to be added?

Fewer chemicals and steps does not mean nothing has to be added. Ozone is toxic, so you need complete ozone generation, destruction and detection equipment; for ozone safety rules, see What is ozone water.

Adopting ozone microbubbles: what is eliminated and what must be added (compiled by DEYly)
Details
Process steps eliminatedPlasma ashing (photoresist strip), SPM/SC-2/SC-1 chemical treatment, 80℃ hot-water rinse
Chemicals eliminatedSulfuric acid, hydrochloric acid, ammonia, hydrogen peroxide, and the associated waste liquid treatment
Equipment eliminatedPlasma asher (photoresist strip stage)
Conditions loweredMaximum process temperature drops from 120℃ (SPM) to 60℃
Equipment to addOzone generator, microbubble generator (wetted parts must be all-fluoropolymer and metal-free), ozone destruction unit, chamber exhaust and ozone detectors, and a CO₂ supply for resistivity adjustment
Still retainedUltrapure-water rinse and drying; dilute hydrofluoric acid when metal removal requires the lowest residue

The product brochure also states that “chemical costs drop by 90% or more and waste liquid treatment costs by 50% or more,” but the brochure gives no test conditions, so we do not treat these as figures you can apply directly; how much your line can save must be calculated from your current chemical usage and trial results.

Which stage should you start with?

  1. Start with the stage that has the least impact

    We suggest starting with rinsing or photoresist stripping. Rinsing just replaces ultrapure water with microbubble water and does not change the chemicals; in one device maker's evaluation, rinse time was cut by 20% (see Semiconductor equipment parts and cleaning tool tests).

  2. Set pass/fail criteria

    For photoresist stripping, look at residue and strip rate; for metal removal, the residue of each metal; for particle removal, particle counts and roughness. Agree on measurement methods and thresholds before the trial.

  3. Run a controlled comparison on the same batch of samples

    Split the same wafers into two groups: one with your current process, one with ozone microbubbles, keeping all other conditions the same. Only then can you tell whether the difference comes from the microbubbles.

  4. Convert results into production-line figures

    Convert the trial results into per-wafer processing time, chemical and water usage, and the equipment and safety requirements to be added, then decide whether to adopt it and for which stages.

For the trial process and deliverables, see Cleaning process trial evaluation.

FAQ

Which process steps can ozone microbubble cleaning eliminate?

Under the replacement process compiled by DEYly, photoresist stripping goes from 4 steps (ashing, SPM, hot-water rinse, ultrapure-water rinse) to 2 and the asher is eliminated; metal contamination removal (replacing SC-2) and particle removal (replacing SC-1) each go from 3 steps to 2. Across the three stages, the total drops from 10 steps to 6, and the 80℃ hot-water rinse is no longer needed.

Can ozone microbubbles completely replace RCA cleaning?

Not necessarily. We propose using ozone microbubbles to replace SC-1 and SC-2 separately, but for the lowest metal residue the evaluation added a dilute hydrofluoric acid step, and there is no test data for particle removal yet. Whether it can fully replace RCA cleaning depends on your requirements for particles, metals and roughness, and must be confirmed with a trial on your own wafers.

What equipment needs to be added to adopt ozone microbubbles?

You need to add an ozone generator, a microbubble generator (wetted parts must be all-fluoropolymer and metal-free), an ozone destruction unit, chamber exhaust and ozone detectors, and a CO₂ supply for resistivity adjustment. What is eliminated is the asher, strong acid and base chemicals, and the hot-water rinse.

How much can you save on chemicals and waste liquid treatment?

The product brochure says chemical costs can drop by 90% or more and waste liquid treatment costs by 50% or more, but the brochure gives no test conditions. How much you can actually save must be calculated from your current chemical usage, waste treatment unit costs and trial results.

Source

  1. Wikipedia, “RCA clean”, 2026-10-26. Link
  2. Wikipedia, “Piranha solution”, 2026-10-23. Link
  3. Wikipedia, “Plasma ashing”, 2026-10-23. Link
  4. Journal of Photopolymer Science and Technology, 28(2), 293–298, "Effect of Microbubbles on Ozonized Water for Photoresist Removal (Takahashi, Horibe, Matsuura, Tatera)", 2015-05-11. Link
  5. 表面と真空 (Vacuum and Surface Science), 61(2), 64–69, "Fundamental Properties of Microbubble in Semiconductor Cleaning Technology (Takahashi)", 2018-02-10. Link
Ask us

Can't find the answer? Ask us directly

Tell us what you're facing. DEYly's engineering and market teams will help assess it and give you initial recommendations.